810-RAD-0012-C1G0A-1E
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 3/4" NPT, 1.2" U, SST, Lens, CSA
Price
Request a Quote
Stock
3 In Stock
Product Series Specifications
Specifications
Brand
Applications
- Flow
- Level
- Interface
Principle of Operation
- Thermal, Calorimetric
Sensor, Probe Style
- Insertion Threaded
NPT Connection
- 1/2” NPT Male
- 3/4” NPT Male
- 1” NPT Male
- 1-1/4” NPT Male
- 1-1/2” NPT Male
- 2” NPT Male
Insertion 'U' Length
- 1.2” (3 cm)
- 2” (5 cm)
- 3” (7.5 cm)
- 4” (10.1 cm)
- 6” (15.2 cm)
- 9” (23 cm)
- 12” (30 cm)
- 18” (46 cm)
- Custom Lengths from 6.4 cm to 305 cm (in 1 cm increments)
- Custom Lengths from 2.5” to 120” (in 1/2” increments)
Wetted Materials
- 316, 316L Stainless Steel
- Hastelloy C-276
- Titanium
Operating Pressure - Sensor
- CSA - All Process Connections: Max. Working Pressure: 3481 psi (24 MPa)
- CRN - All Process Connections: Max. Working Pressure: 1990 psi (13.72 MPa), Material: 316/316L Stainless Steel
- Canadian Registration Number (CRN): 0F22124.2C
Operating Temperature - Sensor
- -55° to 200° C
- -67° to 392° F
Sensor Construction
- All-Welded Construction
Operating Temperature - Electronics
- -55° to 65° C
- -67° to 149° F
Switch Point Range
- Air & Gases: 0.25 to 200 sfps, 0.08 to 60 smps - Standard Condition 21° C (70° F) at 14.7 psi (1 Atm)
- Hydrocarbon-based Liquids: 0.01 to 5.0 fps, 0.003 to 1.50 mps
- Water-based Liquids: 0.01 to 3.00 fps, 0.003 to 0.9 mps
Response Time
- Approximately 0.5 to 30 seconds
Accuracy
- Flow Service: ± 1.0 % of Set Point Velocity over Operating Range of ± 28° C (± 50° F)
- Level Service: ± 0.64 cm (0.25”)
Switch Type
- SPDT Sealed Relay Contacts Rated @ 4 Amps Resistive 230 Vac or 30 Vdc, Max.
Input Power
- 12-24 Vdc, 120-240 Vac, 50/60 Hz
- Power Consumption: 6 Watts Max. Fully Configured
- Universal Power Input
Output
- 4-20 mA (Thermal Signal, Scaleable) 120 Vac, Max.
Communication
- Modbus RTU Communication-Alarms, Flow Status & Diagnostics
- RS-485 Using Kayden's Remote Control & Monitoring Software (RCMS) or other Modbus Compatible Software
Approvals & Certifications
- Canadian Standards Association Details:
- CSA Mark with "C" and "US" or with NRTL
- CSA - Maximum Working Pressure: 24 MPa, 3481 PSI, Single Seal when used with the approved Classic 810 Series sensors.
- CSA - Input/Supply Rated 12/24 VDC or 120/240 VDC, 50/60 Hz, 6 W Max.
- CSA - Output/Contacts Rated 120 VAC Max., 30 VDC Max., 4 Amp Max.
- CSA - Ambient Temperature Rating: -55° C to +65° C (-67° F to +149° F)
- CSA - Process Temperature Range: -55° C to +200° C (-67° F to +392° F)
- CSA - Temperature Code: T3
- CSA - Enclosure Type: 4, IP55
- CSA - Local Sensor & Electronics Enclosure: Flameproof, Class I, Div. 1, Groups B, C, D, Ex d IIB + H₂ AEx d IIB + H₂ (Class I, Zone 1, Group IIB + H₂) Enclosure Typical 4, IP55 Single Seal Approved Per ANSI/ISA 12.27.01-2003
- CSA - Remote Electronics Enclosure - Optional Flameproof: Class I, Groups B, C, D, Ex d IIB + H₂ AEx d IIB + H₂ (Class I, Zone 1, Groups IIB + H₂)
- Canadian Registration Number Details:
- CRN - All Provinces & Territories of Canada
- CRN - Material: 316/316L Stainless Steel
- CRN - Process Connections: 1/2", 3/4", 1", 1-1/4" & 2" Male NPT
- CRN - Insertion Lengths: 1.2" to 120" (3.0 to 304 cm)
- CRN - Max. Working Pressure: 1990 psi, 13,720 kPa, 137 bar
- CRN - Temperature Range: -55° C to +200° C (-67° F to +392° F)
- CRN - Code of Construction: ASME B31.3
- CRN - Canadian Registration Number: 0F22124.2C
Electronics - Standard Features
- 100% Digital Design. Electronics are Environmentally Sealed
- 4-Adjustable Independent Switch Point Timers
- Automated Redundant Self-Test Diagnostics
- Easy Setup: No Mechanical Jumpers or Trim Pots
- Incrementally Adjustable Heater Power (5 % Steps) with Automatic Over-Range Protection
- Intelligent User Interface with Push-Button & Constant Display of Operation (Flow/Level)
- Start-Up Bypass Timer
- Temperature Compensation
- Temperature Mode*: Process Temperature may be displayed/graphed in Flow/Level Mode
- Display Panel Lock-Out*
- *Configurable only from the Kayden RCM Software
Remote Control & Monitoring Software
- Adjust Relay Modes
- Adjust Set Points 1 & 2
- Load or Save User Settings
- Lock or Unlock the Electronics Display Panel to Protect the Settings
- Modify Heater Settings to Optimize Response Time
- Monitor Operating Status
- Operated Via a Personal Computer Locally or from a Remote Control Center
- Visualize the Actions of the Process Via the Graphical Display
- Many Other Adjustable Features
Environmental Protection
- IP55
- IP67
- NEMA 4X
Local Enclosure Conduit Connection
- 1” NPT Female Conduit Connection
Local Enclosure & Cover Material
- Copper-Free Aluminum (Does Not Exceed 0.4 % Copper)
Local Enclosure Cover
- Glass Lens Cover - Hazardous Areas
- Blind Cover - Hazardous Areas
- Buna-N O-Ring on Cover
Local Enclosure & Cover Finish
- Powder-Coated Polyester TGIC
Remote Electronics Enclosure Cover
- Glass Lens Cover - Flameproof
Remote Electronics Enclosure & Cover Finish
- Powder-Coated Polyester TGIC
Storage Temperature
- Store in a clean & dry environment between -30° & 60° C (-22° & 140° F)
Product Series Documentation
Documentation
Data Sheets
Product Manuals
Application Considerations
Application Notes
- Application Note - Kayden 4-20mA Analog Output pdf 766 KB
- Application Note - Kayden Acid Level Detection pdf 1.4 MB
- Application Note - Kayden Fail Safe pdf 894 KB
- Application Note - Kayden High Level Detection Holding Tank pdf 996 KB
- Application Note - Kayden Leak Detection pdf 1.5 MB
- Application Note - Kayden Monitoring Digester Flow pdf 831 KB
- Application Note - Kayden Oil Water Separation pdf 1.2 MB
- Application Note - Kayden Pulp and Paper Digester Tank pdf 1.1 MB
- Application Note - Kayden Pulp and Paper Skimmer Tank pdf 829 KB
- Application Note - Kayden Pump Monitoring and Protection pdf 1.0 MB
- Application Note - Kayden Pump Monitoring and Protection Remote pdf 1.2 MB
Catalogs
Certifications & Approvals
Outline Drawings
- 2020 Outline Dimension Drawing - Drawing A - Kayden CLASSIC 810 - Local Enclosure 1/2" MNPT pdf 190 KB
- 2020 Outline Dimension Drawing - Drawing B - Kayden CLASSIC 810 - Local Enclosure 3/4" MNPT pdf 194 KB
- 2020 Outline Dimension Drawing - Drawing C - Kayden CLASSIC 810 - Local Enclosure 1" MNPT pdf 184 KB
- 2020 Outline Dimension Drawing - Drawing D - Kayden CLASSIC 810 - Local Enclosure 1-1/4" MNPT pdf 187 KB
- 2020 Outline Dimension Drawing - Drawing E - Kayden CLASSIC 810 - Local Enclosure 1-1/2" MNPT pdf 188 KB
- 2020 Outline Dimension Drawing - Drawing F - Kayden CLASSIC 810 - Local Enclosure 2" MNPT pdf 221 KB
- 2020 Outline Dimension Drawing - Drawing G - Kayden CLASSIC 810 - Remote Enclosure 1/2" MNPT pdf 952 KB
- 2020 Outline Dimension Drawing - Drawing H - Kayden CLASSIC 810 - Remote Enclosure 3/4" MNPT pdf 950 KB
- 2020 Outline Dimension Drawing - Drawing I - Kayden CLASSIC 810 - Remote Enclosure 1" MNPT pdf 949 KB
- 2020 Outline Dimension Drawing - Drawing J - Kayden CLASSIC 810 - Remote Enclosure 1-1/4" MNPT pdf 958 KB
- 2020 Outline Dimension Drawing - Drawing K - Kayden CLASSIC 810 - Remote Enclosure 1-1/2" MNPT pdf 963 KB
- 2020 Outline Dimension Drawing - Drawing L - Kayden CLASSIC 810 - Remote Enclosure 2" MNPT pdf 953 KB
- Legacy Outline Dimension Drawing - Drawing A - Kayden CLASSIC 810 - Local Enclosure 1/2" MNPT pdf 330 KB
- Legacy Outline Dimension Drawing - Drawing B - Kayden CLASSIC 810 - Local Enclosure 3/4" MNPT pdf 321 KB
- Legacy Outline Dimension Drawing - Drawing C - Kayden CLASSIC 810 - Local Enclosure 1" MNPT pdf 315 KB
- Legacy Outline Dimension Drawing - Drawing D - Kayden CLASSIC 810 - Local Enclosure 1-1/4" MNPT pdf 311 KB
- Legacy Outline Dimension Drawing - Drawing E - Kayden CLASSIC 810 - Local Enclosure 1-1/2" MNPT pdf 321 KB
- Legacy Outline Dimension Drawing - Drawing F - Kayden CLASSIC 810 - Local Enclosure 2" MNPT pdf 312 KB
- Legacy Outline Dimension Drawing - Drawing G - Kayden CLASSIC 810 - Remote Enclosure 1/2" MNPT pdf 738 KB
- Legacy Outline Dimension Drawing - Drawing H - Kayden CLASSIC 810 - Remote Enclosure 3/4" MNPT pdf 720 KB
- Legacy Outline Dimension Drawing - Drawing I - Kayden CLASSIC 810 - Remote Enclosure 1" MNPT pdf 721 KB
- Legacy Outline Dimension Drawing - Drawing J - Kayden CLASSIC 810 - Remote Enclosure 1-1/4" MNPT pdf 714 KB
- Legacy Outline Dimension Drawing - Drawing K - Kayden CLASSIC 810 - Remote Enclosure 1-1/2" MNPT pdf 718 KB
- Legacy Outline Dimension Drawing - Drawing L - Kayden CLASSIC 810 - Remote Enclosure 2" MNPT pdf 723 KB
Frequently Bought With
Similar SKUs
810-RAC-0012-C1G0A-1E
Kayden CLASSIC 810 Thermal Flow, Level & Interface Switch
Kayden Instruments
Request a Quote
1 In Stock
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 1/2" NPT, 1.2" U, SST, Lens, CSA
810-RAD-0012-C1G0A-3E
Kayden CLASSIC 810 Thermal Flow, Level & Interface Switch
Kayden Instruments
Request a Quote
3 In Stock
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 3/4" NPT, 1.2" U, SST, Lens, CRN
810-RAD-0020-C1G0A-1E
Kayden CLASSIC 810 Thermal Flow, Level & Interface Switch
Kayden Instruments
Request a Quote
2 In Stock
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 3/4" NPT, 2" U, SST, Lens, CSA
810-RAD-0030-C1G0A-1E
Kayden CLASSIC 810 Thermal Flow, Level & Interface Switch
Kayden Instruments
Request a Quote
3 In Stock
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 3/4" NPT, 3" U, SST, Lens, CSA
810-RAD-0040-C1G0A-1E
Kayden CLASSIC 810 Thermal Flow, Level & Interface Switch
Kayden Instruments
Request a Quote
3 In Stock
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 3/4" NPT, 4" U, SST, Lens, CSA
810-RAD-0090-C1G0A-1E
Kayden CLASSIC 810 Thermal Flow, Level & Interface Switch
Kayden Instruments
Request a Quote
1 In Stock
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 3/4" NPT, 9" U, SST, Lens, CSA
810-RAE-0012-C1G0A-3E
Kayden CLASSIC 810 Thermal Flow, Level & Interface Switch
Kayden Instruments
Request a Quote
3 In Stock
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 1" NPT, 1.2" U, SST, Lens, CRN/CSA
810-RAE-0030-C1G0A-1E
Kayden CLASSIC 810 Thermal Flow, Level & Interface Switch
Kayden Instruments
Request a Quote
In Stock 1 - 5 days
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 1" NPT, 3" U, SST, Lens, CSA