Images are representations only.

KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 1" NPT, 6" U, SST, Lens, CRN

Price
Request a Quote
Stock
In Stock 2 - 5 days

Specifications

Applications

  • Flow
  • Level
  • Interface

Principle of Operation

  • Thermal, Calorimetric

Sensor, Probe Style

  • Insertion Threaded

NPT Connection

  • 1/2” NPT Male
  • 3/4” NPT Male
  • 1” NPT Male
  • 1-1/4” NPT Male
  • 1-1/2” NPT Male
  • 2” NPT Male

Insertion 'U' Length

  • 1.2” (3 cm)
  • 2” (5 cm)
  • 3” (7.5 cm)
  • 4” (10.1 cm)
  • 6” (15.2 cm)
  • 9” (23 cm)
  • 12” (30 cm)
  • 18” (46 cm)
  • Custom Lengths from 6.4 cm to 305 cm (in 1 cm increments)
  • Custom Lengths from 2.5” to 120” (in 1/2” increments)

Wetted Materials

  • 316, 316L Stainless Steel
  • Hastelloy C-276
  • Titanium

Operating Pressure - Sensor

  • CSA - All Process Connections: Max. Working Pressure: 3481 psi (24 MPa)
  • CRN - All Process Connections: Max. Working Pressure: 1990 psi (13.72 MPa), Material: 316/316L Stainless Steel
  • Canadian Registration Number (CRN): 0F22124.2C

Operating Temperature - Sensor

  • -55° to 200° C
  • -67° to 392° F

Sensor Construction

  • All-Welded Construction

Operating Temperature - Electronics

  • -55° to 65° C
  • -67° to 149° F

Switch Point Range

  • Air & Gases: 0.25 to 200 sfps, 0.08 to 60 smps - Standard Condition 21° C (70° F) at 14.7 psi (1 Atm)
  • Hydrocarbon-based Liquids: 0.01 to 5.0 fps, 0.003 to 1.50 mps
  • Water-based Liquids: 0.01 to 3.00 fps, 0.003 to 0.9 mps

Response Time

  • Approximately 0.5 to 30 seconds

Accuracy

  • Flow Service: ± 1.0 % of Set Point Velocity over Operating Range of ± 28° C (± 50° F)
  • Level Service: ± 0.64 cm (0.25”)

Switch Type

  • SPDT Sealed Relay Contacts Rated @ 4 Amps Resistive 230 Vac or 30 Vdc, Max.

Input Power

  • 12-24 Vdc, 120-240 Vac, 50/60 Hz
  • Power Consumption: 6 Watts Max. Fully Configured
  • Universal Power Input

Output

  • 4-20 mA (Thermal Signal, Scaleable) 120 Vac, Max.

Communication

  • Modbus RTU Communication-Alarms, Flow Status & Diagnostics
  • RS-485 Using Kayden's Remote Control & Monitoring Software (RCMS) or other Modbus Compatible Software

Approvals & Certifications

  • Canadian Standards Association Details:
  • CSA Mark with "C" and "US" or with NRTL
  • CSA - Maximum Working Pressure: 24 MPa, 3481 PSI, Single Seal when used with the approved Classic 810 Series sensors.
  • CSA - Input/Supply Rated 12/24 VDC or 120/240 VDC, 50/60 Hz, 6 W Max.
  • CSA - Output/Contacts Rated 120 VAC Max., 30 VDC Max., 4 Amp Max.
  • CSA - Ambient Temperature Rating: -55° C to +65° C (-67° F to +149° F)
  • CSA - Process Temperature Range: -55° C to +200° C (-67° F to +392° F)
  • CSA - Temperature Code: T3
  • CSA - Enclosure Type: 4, IP55
  • CSA - Local Sensor & Electronics Enclosure: Flameproof, Class I, Div. 1, Groups B, C, D, Ex d IIB + H₂ AEx d IIB + H₂ (Class I, Zone 1, Group IIB + H₂) Enclosure Typical 4, IP55 Single Seal Approved Per ANSI/ISA 12.27.01-2003
  • CSA - Remote Electronics Enclosure - Optional Flameproof: Class I, Groups B, C, D, Ex d IIB + H₂ AEx d IIB + H₂ (Class I, Zone 1, Groups IIB + H₂)
  • Canadian Registration Number Details:
  • CRN - All Provinces & Territories of Canada
  • CRN - Material: 316/316L Stainless Steel
  • CRN - Process Connections: 1/2", 3/4", 1", 1-1/4" & 2" Male NPT
  • CRN - Insertion Lengths: 1.2" to 120" (3.0 to 304 cm)
  • CRN - Max. Working Pressure: 1990 psi, 13,720 kPa, 137 bar
  • CRN - Temperature Range: -55° C to +200° C (-67° F to +392° F)
  • CRN - Code of Construction: ASME B31.3
  • CRN - Canadian Registration Number: 0F22124.2C

Electronics - Standard Features

  • 100% Digital Design. Electronics are Environmentally Sealed
  • 4-Adjustable Independent Switch Point Timers
  • Automated Redundant Self-Test Diagnostics
  • Easy Setup: No Mechanical Jumpers or Trim Pots
  • Incrementally Adjustable Heater Power (5 % Steps) with Automatic Over-Range Protection
  • Intelligent User Interface with Push-Button & Constant Display of Operation (Flow/Level)
  • Start-Up Bypass Timer
  • Temperature Compensation
  • Temperature Mode*: Process Temperature may be displayed/graphed in Flow/Level Mode
  • Display Panel Lock-Out*
  • *Configurable only from the Kayden RCM Software

Remote Control & Monitoring Software

  • Adjust Relay Modes
  • Adjust Set Points 1 & 2
  • Load or Save User Settings
  • Lock or Unlock the Electronics Display Panel to Protect the Settings
  • Modify Heater Settings to Optimize Response Time
  • Monitor Operating Status
  • Operated Via a Personal Computer Locally or from a Remote Control Center
  • Visualize the Actions of the Process Via the Graphical Display
  • Many Other Adjustable Features

Environmental Protection

  • IP55
  • IP67
  • NEMA 4X

Local Enclosure Conduit Connection

  • 1” NPT Female Conduit Connection

Local Enclosure & Cover Material

  • Copper-Free Aluminum (Does Not Exceed 0.4 % Copper)

Local Enclosure Cover

  • Glass Lens Cover - Hazardous Areas
  • Blind Cover - Hazardous Areas
  • Buna-N O-Ring on Cover

Local Enclosure & Cover Finish

  • Powder-Coated Polyester TGIC

Remote Electronics Enclosure Cover

  • Glass Lens Cover - Flameproof

Remote Electronics Enclosure & Cover Finish

  • Powder-Coated Polyester TGIC

Storage Temperature

  • Store in a clean & dry environment between -30° & 60° C (-22° & 140° F)

Documentation

Outline Drawings

Similar SKUs

810-RAD-0060-C1G0A-3E
810-RAD-0060-C1G0A-3E
Kayden CLASSIC 810 Thermal Flow, Level & Interface Switch
Kayden Instruments
Request a Quote
In Stock 2 - 5 days
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 3/4" NPT, 6" U, SST, Lens, CRN
810-RAE-0012-C1G0A-3E
810-RAE-0012-C1G0A-3E
Kayden CLASSIC 810 Thermal Flow, Level & Interface Switch
Kayden Instruments
Request a Quote
3 In Stock
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 1" NPT, 1.2" U, SST, Lens, CRN/CSA
810-RAE-0020-C1G0A-3E
810-RAE-0020-C1G0A-3E
Kayden CLASSIC 810 Thermal Flow, Level & Interface Switch
Kayden Instruments
Request a Quote
In Stock 2 - 5 days
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 1" NPT, 2" U, SST, Lens, CRN
810-RAE-0030-C1G0A-3E
810-RAE-0030-C1G0A-3E
Kayden CLASSIC 810 Thermal Flow, Level & Interface Switch
Kayden Instruments
Request a Quote
In Stock 2 - 5 days
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 1" NPT, 3" U, SST, Lens, CRN
810-RAE-0040-C1G0A-3E
810-RAE-0040-C1G0A-3E
Kayden CLASSIC 810 Thermal Flow, Level & Interface Switch
Kayden Instruments
Request a Quote
In Stock 2 - 5 days
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 1" NPT, 4" U, SST, Lens, CRN/CSA
810-RAE-0060-C1B0A-3E
810-RAE-0060-C1B0A-3E
Kayden CLASSIC 810 Thermal Flow, Level & Interface Switch
Kayden Instruments
Request a Quote
In Stock 2 - 5 days
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 1" NPT, 6" U, SST, Blind, CRN/CSA
810-RAE-0060-C1G0A-1E
810-RAE-0060-C1G0A-1E
Kayden CLASSIC 810 Thermal Flow, Level & Interface Switch
Kayden Instruments
Request a Quote
In Stock 2 - 5 days
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 1" NPT, 6" U, SST, Lens, CSA
810-RAE-I0080-C1G0A-3E
810-RAE-I0080-C1G0A-3E
Kayden CLASSIC 810 Thermal Flow, Level & Interface Switch
Kayden Instruments
Request a Quote
In Stock 1 - 2 weeks
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 1" NPT, 8" U, SST, Lens, CRN