Insertion 'U' Length - Custom
- 6.4 cm to 305 cm (in 1 cm increments)
- 2.5” to 120” (in 1/2” increments)
Flange Type
- RF - Raised Face
- RTJ - Ring Typical Joint
Flange Size
- 1" DN 25
- 1-1/2" DN 40
- 2" DN 50
- 3" DN 80
- 4" DN 100
- 5" DN 125
- 6" DN 150
- 8" DN 200
- 10" DN 250
Flange Material
- 316, 316L Stainless Steel
- Hastelloy C-276
- Titanium Grade 2
- Other metals available
Wetted Materials
- 316, 316L Stainless Steel
- Hastelloy C-276
- Titanium Grade 2
Operating Pressure Maximum - Sensor
- Per Flange Rating, ASME B16.5
Operating Temperature - Sensor
- -55° to 200° C
- -67° to 392° F
Operating Temperature - Electronics
- -55° to 65° C
- -67° to 149° F
Switch Point Range
- Air & Gases: 0.25 to 200 sfps, 0.08 to 60 smps - Standard Condition 21° C (70° F) at 14.7 psi (1 Atm)
- Hydrocarbon-based Liquids: 0.01 - 5.0 fps, 0.003 - 1.50 mps
- Water-based Liquids: 0.01 - 3.00 fps, 0.003 - 0.9 mps
Response Time
- Approximately 0.5 to 30 seconds
Accuracy
- Flow Service: ± 1.0 % of Set Point Velocity over Operating Range of ± 28° C (± 50° F)
- Level Service: ± 0.64 cm (0.25”)
Switch Type
- 2 SPDT Sealed Relay Contacts Rated @ 4 Amps Resistive 230 Vac or 30 Vdc, Max.
Input Power
- 12-24 Vdc, 120-240 Vac, 50/60 Hz
- Power Consumption: 6 Watts Max. Fully Configured
- Universal Power Input
Output
- 4-20 mA (Thermal Signal, Scaleable) Rates 120 Vac, Max.
Communication
- Modbus RTU Communication-Alarms, Flow Status & Diagnostics
- RS-485 Using Kayden's Remote Control & Monitoring Software (RCMS) or other Modbus Compatible Software
Approvals & Certifications
- Canadian Standards Association Details:
- CSA Mark with "C" and "US" or with NRTL
- CSA - Input/Supply Rated 12/24 VDC or 120/240 VDC, 50/60 Hz, 6 W Max.
- CSA - Output/Contacts Rated 120 VAC Max., 30 VDC Max., 4 Amp Max.
- CSA - Ambient Temperature Rating: -55° C to +65° C (-67° F to +149° F)
- CSA - Process Temperature Range: -55° C to +200° C (-67° F to +392° F)
- CSA - Temperature Code: T3
- CSA - Enclosure Type: 4, IP55
- CSA - Local (Sensor) Enclosure Flameproof: Class I, Div. 1, Groups B, C, D, Ex d IIB + H₂ AEx d IIB + H₂ (Class I, Zone 1, Group IIB + H₂) Temperature Code: T3 Enclosure Typical 4, IP55 Single Seal Approved Per ANSI/ISA 12.27.01-2003
- CSA - Remote Electronics Enclosure - Optional Flameproof: Class I, Groups B, C, D, Ex d IIB + H₂ AEx d IIB + H₂ (Class I, Zone 1, Groups IIB + H₂) Temperature Code: T3
- Canadian Registration Number Details:
- CRN - All Provinces & Territories of Canada
- CRN - Material: 316/316L Stainless Steel
- CRN - Process Connections: Class 150, 300, 600, 900. 1 to 10 NPS.
- CRN - Insertion Lengths: 2.5" to 120" (6.35 to 304 cm)
- CRN - Maximum Working Pressures:
- CRN - Class 150: MWP* : 275 psi, 1896 kPa, 18.96 bar
- CRN - Class 300: MWP* : 720 psi, 4964 kPa, 49.64 bar
- CRN - Class 600: MWP* : 1440 psi, 9928 kPa, 99.28 bar
- CRN - Class 900: MWP* : 1990 psi, 13,720 kPa, 137.20 bar
- * Pressure derated by temperature and per the rating of the flange class. ASME B16.5-2020, Table 2-2.2C.
- CRN - Temperature Range: -55° C to +200° C (-67° F to +392° F)
- CRN - Code of Construction: ASME B31.3
- CRN - Canadian Registration Numbers - 1” & 1-1/2” - Flanges Approved for All Provinces & Territories 812-RAA Series: CRN # 0F13787.2C 316, 316L Stainless Steel, Pipe NPS 1/2” Schedule 80 Code of Construction: ASME B31.3, Max.
- CRN - Canadian Registration Numbers - 2” through 10” Flanges - Approved for All Provinces & Territories 812-RAA Series: CRN # 0F13773.2C 316, 316L Stainless Steel, Pipe NPS 3/4” Schedule 80 Code of Construction: ASME B31.3, Max.
Electronics - Standard Features
- *Configurable only from the Kayden RCM Software
- 100 % Digital Design. Electronics are Environmentally Sealed
- 4-Adjustable Independent Switch Point Timers
- Automated Redundant Self-Test Diagnostics
- Display Panel Lock-Out*
- Easy Setup: No Mechanical Jumpers or Trim Pots
- Incrementally Adjustable Heater Power (5 % Steps) with Automatic Over-Range Protection
- Intelligent User Interface with Push-Button & Constant Display of Operation (Flow/Level)
- Start-Up Bypass Timer
- Temperature Compensation
- Temperature Mode*: Process Temperature may be Displayed/Graphed in Flow/Level Mode
Remote Control & Monitoring Software
- Adjust Relay Modes
- Adjust Set Points 1 & 2
- Load or Save User Settings
- Lock or Unlock the Display Panel to Protect the Settings
- Many Other Adjustable Features
- Modify Heater Settings to Optimize Response Time
- Monitor Operating Status
- Operated Via a Personal Computer Locally or from a Remote Control Center
- Visualize the Actions of the Process Via the Graphical Display
Local Enclosure Conduit Connection
- 1” NPT Female Conduit Connection
Local Enclosure & Cover Material
- Copper-Free Aluminum (Does Not Exceed 0.4 % Copper)
Local Enclosure Cover
- Buna-N O-Ring on Cover
- Blind Cover - Flameproof
- Glass Lens Cover - Flameproof
Local Enclosure & Cover Finish
- Powder-Coated Polyester TGIC
Remote Electronics Enclosure Cover
- Glass Lens Cover - Flameproof
Remote Electronics Enclosure & Cover Finish
- Powder-Coated Polyester TGIC
Storage Temperature
- Store in a clean & dry environment between -30° & 60° C (-22° & 140° F)