Images are representations only.

Kayden CLASSIC 810 Spare Sensor, 1/2" thru 2" MNPT, P02 Series

Brand: Kayden Instruments
  • Replacement Sensor for Kayden CLASSIC 810 Series
  • Process Connections - Male NPT
    • 1/2"
    • 3/4"
    • 1"
    • 1-1/4"
    • 1-1/2"
    • 2"
  • Insertion 'U' Lengths
    • 1.2" (3.0 cm)
    • 2" (5.0 cm)
    • 4" (10.1 cm)
    • 6" (15.2 cm)
    • 9" (22.8 cm)
    • 12" (30.4 cm)
    • 18" (45.7 cm)
    • Custom lengths from 2.5" to 120" (6.0 cm to 305 cm) in 1/2" (1 cm) increments
  • Adjustable Set Point Range
    • 0-254 feet/s, 0-77 meters/s
  • Input Power
    • 12-24 Vdc & 115-230 Vac, 50-60 Hz
  • Operating Pressure (Maximum)
    • CSA: 3480 psi, 24,000 kPa, 240 bar
    • CRN: 1990 psi, 13721 kPa, 137.2  bar
  • Temperature Range (Sensor)
    • -45° to 200° C, -50° to 392° F
  • Wetted Materials
    • 316 Stainless Steel
    • Other Metals Available
  • Sensor Connection
    • Molex 8-Pin
  • Approvals (with Classic 810 switch)
    • CSA, CRN, Single Seal, NACE
  • Replacement Sensor for Kayden CLASSIC 810 Series
  • Process Connections - Male NPT
    • 1/2"
    • 3/4"
    • 1"
    • 1-1/4"
    • 1-1/2"
    • 2"
  • Insertion 'U' Lengths
    • 1.2" (3.0 cm)
    • 2" (5.0 cm)
    • 4" (10.1 cm)
    • 6" (15.2 cm)
    • 9" (22.8 cm)
    • 12" (30.4 cm)
    • 18" (45.7 cm)
    • Custom lengths from 2.5" to 120" (6.0 cm to 305 cm) in 1/2" (1 cm) increments
  • Adjustable Set Point Range
    • 0-254 feet/s, 0-77 meters/s
  • Input Power
    • 12-24 Vdc & 115-230 Vac, 50-60 Hz
  • Operating Pressure (Maximum)
    • CSA: 3480 psi, 24,000 kPa, 240 bar
    • CRN: 1990 psi, 13721 kPa, 137.2  bar
  • Temperature Range (Sensor)
    • -45° to 200° C, -50° to 392° F
  • Wetted Materials
    • 316 Stainless Steel
    • Other Metals Available
  • Sensor Connection
    • Molex 8-Pin
  • Approvals (with Classic 810 switch)
    • CSA, CRN, Single Seal, NACE
Models matching criteria: 6
KAYDEN CLASSIC 800 Series Thermal Flow, Level, Interface Sensor, 1" NPT, 18" U, SST, CRN
In Stock 3 - 5 days
$894.98 USD
$72.99 Shipping
KAYDEN CLASSIC 800 Series Thermal Flow, Level, Interface Sensor, 1-1/2" NPT, 9" U, SST, CRN
In Stock 2 - 4 weeks
$696.42 USD
$72.99 Shipping
KAYDEN CLASSIC 800 Series Thermal Flow, Level, Interface Sensor, 1-1/2" NPT, 4.5" U, SST, CRN
2 In Stock
$481.07 USD
$72.99 Shipping
Non-Cancellable / Non-Refundable
KAYDEN CLASSIC 800 Series Thermal Flow, Level, Interface Sensor, 1-1/2" NPT, 4" U, SST, CRN
In Stock 3 - 5 days
$530.71 USD
$72.99 Shipping
KAYDEN CLASSIC 800 Series Thermal Flow, Level, Interface Sensor, 3/4" NPT, 9" U, SST, CRN
In Stock 1 - 3 days
$597.14 USD
$72.99 Shipping
KAYDEN CLASSIC 800 Series Thermal Flow, Level, Interface Sensor, 1" NPT, 24" U, SST, CRN
3 - 5 days
$381.79 USD
$72.99 Shipping

Specifications

Applications

  • Flow
  • Level
  • Interface

Principle of Operation

  • Thermal, Calorimetric

Insertion 'U' Length

  • 2” (5 cm)
  • 4” (10.1 cm)
  • 6” (15.2 cm)
  • 9” (23 cm)
  • 12” (30 cm)
  • 18” (46 cm)
  • Custom 'U' Lengths 2.5” to 120” (6.4 cm to 305 cm) Available in 1/2” (1 cm) Increments.
  • 1.2” (3 cm)

NPT Connection

  • 1/2” NPT Male
  • 3/4” NPT Male
  • 1” NPT Male
  • 1-1/4” NPT Male
  • 1-1/2” NPT Male
  • 2” NPT Male

Wetted Materials

  • 316, 316L Stainless Steel
  • Hastelloy C-276
  • Titanium
  • Other Metals Available

Operating Pressure - Sensor

  • CSA - All Process Connections: Max. Working Pressure: 3481 psi (24 MPa)
  • CRN - All Process Connections: Max. Working Pressure: 1990 psi (13.72 MPa), Material: 316/316L Stainless Steel
  • CRN - Canadian Registration Number: 0F22124.2C

Operating Temperature - Sensor

  • -45° to 200° C (-50° to 392° F)

Sensor Construction

  • All-Welded Construction

Switch Point Range

  • Air & Gases: 0.25 to 200 sfps, 0.08 to 60 SMPS - Standard Condition 21° C (70° F) at 14.7 psi (1 Atm)
  • Hydrocarbon-based Liquids: 0.01 to 5.0 FPS, 0.003 to 1.50 MPS
  • Water-based Liquids: 0.01 to 3.00 FPS, 0.003 to 0.9 MPS

Response Time

  • As low as 0.5 seconds

Accuracy

  • Flow Service: ± 1.0 % of Set Point Velocity over Operating Range of ± 28° C (± 50° F)
  • Level Service: ± 0.64 cm (0.25”)

Approvals & Certifications

  • CRN - Canadian Registration Numbers 1/2” Male NPT, Approved for All Provinces & Territories Replacement Sensor for Kayden Classic 810-RAC Series

Sensor, Probe Style

  • Insertion

Sensor, Probe Connection Type

  • Molex 8-Pin

Storage Temperature

  • Store in a clean & dry environment between -30° & 60° C (-22° & 140° F)